防護試驗 - IPX7

Test for second characteristic numeral 7: temporary immersion between 0,15 m and 1 m

The test is made by completely immersing the enclosure in water in its service position as specified by the manufacturer so that the following conditions are satisfied:

a) the lowest point of enclosures with a height less than 850 mm is located 1 000 mm below the surface of the water;
b) the highest point of enclosures with a height equal to or greater than 850 mm is located 150 mm below the surface of the water;

c) the duration of the test is 30 min;
d) the water temperature does not differ from that of the equipment by more than 5 K.


However, a modified requirement may be specified in the relevant product standard if the tests are to be made when the equipment is energized and/or its parts in motion.