防護試驗 - IPX7

Test for second characteristic numeral 7: temporary immersion between 0,15 m and 1 m

The test is made by completely immersing the enclosure in water in its service position as specified by the manufacturer so that the following conditions are satisfied:

a) the lowest point of enclosures with a height less than 850 mm is located 1 000 mm below the surface of the water;
b) the highest point of enclosures with a height equal to or greater than 850 mm is located 150 mm below the surface of the water;

c) the duration of the test is 30 min;
d) the water temperature does not differ from that of the equipment by more than 5 K.


However, a modified requirement may be specified in the relevant product standard if the tests are to be made when the equipment is energized and/or its parts in motion.

2014年11月10日 星期一

防護試驗 - IPX6

Test for second characteristic numeral 6 with the 12,5 mm nozzle

The test is made by spraying the enclosure from all practicable directions with a stream of water from a standard test nozzle as shown in figure 6.


The conditions to be observed are as follows:

– internal diameter of the nozzle: 12,5 mm;
– delivery rate: 100 l/min ± 5 %;
– water pressure: to be adjusted to achieve the specified delivery rate;
– core of the substantial stream: circle of approximately 120 mm diameter at 2,5 m distance from nozzle;
– test duration per square metre of enclosure surface area likely to be sprayed: 1 min;
– minimum test duration: 3 min;
– distance from nozzle to enclosure surface: between 2,5 m and 3 m.




防護試驗 - IP6X





防護試驗 - IPX4

Test for second characteristic numeral 4 with oscillating tube or spray nozzle

The test is made using one of the two test devices described in figure 4 and in figure 5 in accordance with the relevant product standard.


Conditions when using the test device as in figure 4 (oscillating tube):
The oscillating tube has spray holes over the whole 180” of the semicircle. The total flow rate is adjusted as specified in table 9 and is measured with a flow meter.

The tube is caused to oscillate through an angle of almost 360°, 180° on either side of the vertical, the time for one complete oscillation (2 × 360°) being about 12 s.
The duration of the test is 10 min.
If not specified otherwise in the relevant product standard, the support for the enclosure under test is perforated so as to avoid acting as a baffle and the enclosure is sprayed from every direction by oscillating the tube to the limit of its travel in each direction.